4-BALL WEAR SCAR TESTÂ XCP LUBRICATE & PROTECT
This test (ASTM D4172) covers a procedure for making a preliminary evaluation of the anti-wear properties of fluid lubricants in sliding contact by means of the Four-Ball Wear Test Machine.
METHOD: Three diameter steel balls are clamped together and covered with the lubricant. A fourth steel ball is pressed with a force of 40 kg into the cavity. The temperature of the test lubricant is regulated at 75°C and then the top ball is rotated at 1200 rpm for 60 min.
The better the lubricant is at preventing wear, the smaller the wear scar will be on the three stationary balls.
RESULTS:
- XCP Lubricate & Protect – wear scar of 0.55 mm
- WD-40 High Performance Lubricant – wear scar of 1.34 mm
- Test results and service experience show wear reduction and lubrication qualities improved by up to 60% when compared to the market leader.